Meter LB-715 is designed for air temperature, relative humidity and air pressure measurement. It is a device of small size, powered from an outside power supply. It is characterized by a modern construction based on efficient and energy saving microprocessor controller.
For measurement the device uses data from a temperature sensor Pt-1000, from a capacitive relative humidity sensor and from a semiconductor pressure sensor. Basing on the knowledge of nonlinear temperature sensor characteristics and digital calibration data stored during the calibration process in a device's non-volatile memory (each device is calibrated separately) the microprocessor counts the actual temperature, relative humidity and pressure measurement. The device does not have its own LCD screen to display the measurement results. The measurement results from LB-715 are sent (in a digital form- current loop) from the device to a supervisory system of data collection: (using converter LB-371 or LB-486) or through an interface RS232C to a PC computer or to a special portable reading panel LB-755, which is provided in as an additional device equipment. The interface parameters allow on sending data and powering the device using one two-cable line of any polarity. The sending line cable length is limited by the cable resistance (the resistance of both cable conductors cannot exceed 100 om).
The device does not have any mechanical calibration elements (i.e.: potentiometers). The calibration of the device is performed by sending calibration data obtained in a model climate conditions through a digital interface to a non-volatile device memory. It guarantees comfort and high calibration accuracy as well as stability of the device's meteorological parameters in time.
Barometer LB-716 is a less complex version of LB-715 in which there are no sensors for humidity and temperature measurement. The measurement results from the barometer LB-716 are sent from the device in a digital form (current loop) to a supervisory system of data collection (using a converter LB-371 or LB-486) or through an interface RS232C to a PC computer or to a special reading panel: stationary LB-724 or portable LB-755 that provide additional device equipment.
Thermometer- hygrometer- barometer LB-715 and barometer LB-716 can be made in a special "S" version (in a silicone filing compound), which makes them resistant to high humidity.
The device's standard version (without the silicone filing) is
adapted for short time (up to few hours) measurements on the ends of
measurement scopes. Except from the measurements the devices in a
standard version should stay in recommended constant work conditions.
Independently from the ("S") version the devices cannot be put into immediate precipitation or water out dropping.
Each thermometer – hygrometer -barometer (barometer) (upon a request) can have an individual calibration certificate issued by the LAB-EL Calibration Laboratory (humidity and temperature measurement) and a certification of proof issued by the Air force Technical Institute in Warsaw (pressure measurement).
TEMPERATURE MEASUREMENT | ||
---|---|---|
Measurement inaccuracy |
+/- 0.1°C | +/- 1 last digit |
Scope of measurement | -40..+85°C | |
Measurement resolution |
0.1°C |
HUMIDITY MEASUREMENT |
||
---|---|---|
Measurement inaccuracy |
+/- 2.0 % | in the scope of 10...90%, +/- 1 last digit |
+/- 4.0% | outside of the scope 10...90% | |
Scope of measurement LB-715 | 10..95 % | for temperatures up to +40 °C |
10..60 % | for temperatures up to +70 °C | |
10..40 % | for temperatures up to +80 °C | |
Measurement resolution |
0.1 % |
PRESSURE MEASUREMENT | ||
---|---|---|
Measurement inaccuracy |
+/- 1.0 hPa | in the scope of 0..+70 °C |
Scope of measurement | 700..1100 hPa | |
Measurement resolution |
0.1 hPa |
RECOMMENDED CONSTANT WORK CONDITIONS *) | |
---|---|
Scope of temperatures |
+5..+40 °C |
Scope of humidity | 20..80 % |
Scope of pressure |
850..1100 hPa |
POWER SUPPLY, TECHNICAL DATA |
||
---|---|---|
Scope of voltage |
8..24V DC | |
Energy consumption |
15mA | average |
25mA | maximum |
|
Casing overall dimensions, material |
185 x 80 x 60 mm | polymas, ABS |
Level of casing protection |
IP 65 | limited additionally by the class of filter protection |
![]() |
Produced by: LAB-EL Laboratory Electronics 68b, Bodycha Str., 02-495 Warsaw tel: (022) 667 71 18, 0601 209656, fax: (022) 867 53 32 e mail: info@label.com.pl home page: http://www.label.com.pl internet meteorological station: http://www.meteo.waw.pl meteorological station on a mobile phone: wap.meteo.waw.pl Last updated: 30.10.2006 |
![]() |