A material hygrometer LB-795 is designed for wood relative humidity measurement (or after adequate programming performed by a user) also for humidity measurement of different materials. It realises three measuring methods:
The hygrometer LB-795 main features:
Technical data for probes: LB-754J
(thermometer) and LB-701 (hytherograph)
are in adequate documents. The hygrometer LB-795 serves only the basic
temperature scope in those probes (-40...+85 °C).
The measurement uncertainty of wood humidity depends on many factors such as: i. e. wood flaws in place of measurement taking, uneven humidity distribution in wood, incorrect way of measurement taking. The influence of those factors (treated each one separately) is not big and should not result in significant influence on a measurement result. In case of simultaneous projection of few of them and their unfavourable accumulation they can lead to significant measurement errors. When taking the measurement one should apply to comments and hints described in adequate chapters of the meter's manual that describe an appropriate way of measurement for each method.
The hygrometer shows wood relative humidity according to a following definition:W[%] = (mass of water contained in wood) / (mass of completely dry wood) * 100
Wood humidity can be divided in two characteristic scopes:Upper hygroscope humidity scope 30% is conventional and for different wood types assumes values from 23% to 33 %.
Meteorological parameters for Electrodes | |
---|---|
Humidity | |
scope | 5...100 % |
resolution | 0,1 % |
Meteorological parameters for needle Probe | ||
---|---|---|
Humidity |
Temperature (LB-754J) | |
scope | 6...100% | -40...85 °C |
resolution | 0,1% | 0,1°C |
absolute measurement uncertainty | +/- 0,5 °C |
Meteorological parameters for RH Probe | ||
---|---|---|
Humidity | Temperature | |
scope | 3...30 % | -40...85 °C |
resolution | 0,1 % | 0,1°C |
absolute measurement uncertainty | +/- 0,2 °C |
POWER SUPPLY | |
---|---|
battery | 4 batteries R6 (AA) |
network |
stabilised feeder 12V DC / 100 mA |
SCOPE OF WORK TEMPERATURES | ||
---|---|---|
Device | Scope | Comments |
Probe LB-701 | -40..+85 °C | Water outdropping is impermissibleie |
Meter LB-795 | 0..+50 °C |
![]() |
Produced by: LAB-EL Laboratory Electronics 68b, Bodycha Str., 02-495 Warsaw tel: (022) 667 71 18, 0601 209656, fax: (022) 867 53 32 e mail: info@label.com.pl home page: http://www.label.com.pl internet meteorological station: http://www.meteo.waw.pl meteorological station on a mobile phone: wap.meteo.waw.pl Last updated: 11.10.2005 |
![]() |