![]() Kafka-1R/Z printer can be an additional recorder |
A readout panel LB-724 is produced in various versions that can cooperate with different LAB-EL measurement devices. A thermal printer KAFKA-1R/Z can be attached (an option upon request) to the panels’ interface of LB-724T and LB-724R, and allow on registry of the current measurement results.
LB-724R readout panel allows on counting the impulses from a rain-gauge – resulting from a rainfall (i.e. ARG-100), it displays the results of an accumulated rainfall, a rainfall from the last 24 hours and allows on looking over an hourly rainfall from the last 64 hours on easy to read LED displays. The fact of exceeding programmed by a user level of an accumulated 24 hour rainfall and an occurrence of a rainfall effect are signaled by small lamps on the front board and on two transmitter outputs. The accumulated rainfall’s value is sent out in a digital form to a supervisory system of data collection. The panel is resistant to lacks in power supply (it does not loose information about a status of the rainfall counters). Controlling the panel’s work is performed through a specialized pilot (a programmer). There is a possibility of attaching a printer KAFKA-1R/Z.
LB-724 panel is used for cooperation with a hytherograph LB-710 or a thermometer LB-710T it is offered under the trade name LB-722C in a climate regulation set LB-720C. This panel (in version 6.0 described below) has extended set of the regulation and alarm functions.
LB-722C readout-control panel (version 6.0) allows on readout of temperature and humidity values measured by the cooperating with it hytherograph LB-710 and registry of one of those two values. The measurement results are displayed on two four digit easy to read LED type displays. The actual measurement results are sent out in a digital form to a supervisory system of data collection (i.e. to a computer or a concentrator LB-731). The panel allows on registry of a measured value of humidity or temperature from the last 64 hours of the device’s work.
Additionally, the panel is equipped with three transmitter outputs
that can be used for maintaining a set value of humidity and
temperature in a chamber or a room and for controlling an alarm
(signaling the exceeds in humidity and temperature values outside the
set thresholds - upper and lower or incorrect device work i.e. a
hytherograph’s damage LB-710).
A remote control transmitter (a pilot) is provided with the panel, because of which, it is possible to view memory containing the registered values of humidity or temperature and change the settings associated with controlling the transmitter outputs. The panel is resistant to lacks of power supply (it does not loose the registered measurement results and the values of the settings associated with controlling the transmitters).
The panel is made in two versions: basic LB-722C and a version with analogue voltage outputs LB-722V.
A readout panel LB-724T allows on the measurements readout from an
eight channel thermometer LB-711. The
measurement’s result and the channel’s number from which the
temperature is read at present are displayed on two four digit easy to
read LED type displays. The measurement results from the following
channels are displayed on the displays in cycles (every few seconds).
The actual temperature values are sent out in a digital form to a
supervisory system of data collection (i.e. to a PC computer). The
panel allows on registry of an average value from all of the measured
temperatures from the last 64 hours of the device’s work or from one
chosen channel of temperature measurement. Additionally, the panel is
equipped with three transmitter outputs that can be used for
maintaining a set temperature value in a chamber or a room (heather
control) and for alarm’s control (signaling of an exceed in a set
temperature value or incorrect device work). Such control is done based
on an average value from all of working measurement channels of a
thermometer LB-711 or from one of the chosen channels of temperature
measurement.
A remote control transmitter (a pilot) is provided with the panel, because of which, it is possible to view the memory with the registered average temperature values and change the settings associated with controlling the transmitter outputs. The panel is resistant to lacks of power supply (it does not loose registered temperature values). There is a possibility of attaching a printer KAFKA-1R/Z.
A readout panel LB-724P allows on readout and registry of the atmospheric pressure measured values using cooperating with it barometer LB-716 or repetition of the results displayed by a barometer LB-750. The measurement results and a trend value in pressure change are displayed on two four digit, easy to read LED type displays. The actual pressure value is sent out in a digital form to a supervisory system of data collection (i.e. to a computer). The panel allows on registry of the measured pressure values from the last 64 hours of the device’s work. Additionally the panel is equipped with three transmitter outputs that can be used for maintaining a set pressure value in a chamber or a room (pump control) and for controlling the alarm (signaling the exceeds in set pressure value or incorrect device work).
A remote control transmitter (a pilot) is provided with the panel, because of which, it is possible to view the memory with the registered pressure values and change the settings associated with controlling the transmitter outputs. The panel is resistant to lacks of power supply (it does not loose registered pressure values).
A readout panel LB-724Dx allows on readout and registry of the
measured pressure difference values using cooperating with it a
differential pressure meter LB-716Dx. The measurement results and a
trend value in pressure change are displayed on two four digit, easy to
read LED type displays. The actual value of the pressure difference is
sent out in a digital form to a supervisory system of data collection
(i.e. to a computer). The panel allows on registry of the measured
pressure difference value from the last 64 hours of the device’s work.
Additionally the panel is equipped with three transmitter outputs that
can be used for maintaining a set value of pressure difference in a
chamber or a room (pump control) and for controlling the alarm
(signaling the exceeds in set pressure difference value or incorrect
device work).
A remote control transmitter (a pilot) is provided with the panel, because of which, it is possible to view the memory with the registered pressure difference values and change the settings associated with controlling the transmitter outputs. The panel is resistant to lacks of power supply (it does not loose registered pressure values).
A readout panel LB-724W allows on readout of wind speed and direction and registry of maximum values of a wind speed measured by cooperating with it anemometer LB-746. The measurement results are displayed on two four digit, easy to read LED type displays. The actual measurement values are sent out in a digital form to a supervisory system of data collection (i.e. to a computer). The panel allows on registry of maximum values of measured wind speed and blast from the last 64 hours of the device’s work. Additionally the panel is equipped with three transmitter outputs that can be used for signaling the exceeds by the measured values of programmed thresholds and signaling incorrect device work).
A remote control transmitter (a pilot) is provided with the panel,
because of which, it is possible to view the memory with registered
maximum wind blasts and change the settings associated with controlling
the transmitter outputs. The panel is resistant to lacks of power
supply (it does not loose registered pressure values).
![]() |
Producent: LAB-EL Elektronika Laboratoryjna Sp. J. ul. Bodycha 68b, 02-495 Warszawa tel: (022) 667 71 18, 0601 209656, fax: (022) 867 53 32 poczta elektroniczna: info@label.com.pl witryna internetowa: http://www.label.com.pl internetowa stacja meteorologiczna: http://www.meteo.waw.pl stacja meteorologiczna w komórce: wap.meteo.waw.pl Ostatnia aktualizacja: 24.04.2008 |
![]() |