External temperature sensor casings with a thermo-resistor Pt1000 (or upon a special request Pt100)) for thermometers LB-471T, LB-701T, LB-706T, LB-708T, LB-708TR, LB-710T, LB-710DT, LB-711, LB-754J i LB-754T. The sensors can be made in different construction versions that define the scope of work temperatures and the range of usage. A client defines type and length of a cable connecting a sensor’s casing with a reading panel. The standard version of a sensor’s cable is 1 m in length, other lengths upon a request.
The scope of measurement of a thermometer with a sensor is not
bigger than thermometer scope of measurement and not bigger than the
scope of sensor work temperatures. The scope of temperatures provided
below concerns a sensor’s ending where a thermo-resistor is located.
The scope of sensors temperatures from the cable’s input side is
limited by the scope of temperatures of a cable coming from a sensor.
The sensor can be immersed in a medium of temperature enclosed in the
scope of sensor work temperatures only to such depth so its end from
the input’s side does not exceed the cable work temperatures.
TEMPERATURE SENSOR TL-1 | |||
Type | Scope of temperatures | Overall dimensions | Usage, comments |
TL-1 | -40..+85°C | diameter 23 mm, L=192 mm | For air. Plastic casing (ABS). Standard cable work
temperature (PCV): -5..+70°C (without bending: -30..+80°C). |
![]() |
TEMPERATURE SENSORS TL-2, TL-3, TL-4 | |||
Type | Scope of temperatures | Overall dimensions | Usage, comments |
TL-2 | -60..+80°C | diameter 6 mm, L=67...250 mm (standard 100 mm | For liquids, semi fluid masses, ground, air.
Casing made out of stainless steel, PCV cable, seal connection using a
thermo-shrinkable jacket. Standard cable work temperature:
-5..+70°C
(without bending: -30..+80°C). |
TL-3 | diameter 10 mm, L=200...800 mm (standard 400 mm) | ||
TL-4 | diameter 4,1 mm, L=60...150 mm (standard 100 mm) | ||
![]() |
TEMPERATURE SENSOR TA-PL |
|||
Type | Scope of temperatures | Overall dimensions | Usage, comments |
TA-PL-3 TA-PL-4 TA-PL-5 TA-PL-6 TA-PL-8 TA-PL-10 |
-50..+250°C -100..+250°C -50..+400°C |
diameter: 3, 4, 5, 6, 8, albo 10 mm, L=100...1000 mm |
For gases and liquids in containers. Cable output
form sensors – straight or angular. Scope of cable work temperatures: standard (PCV): -20..+80°C, silicone: -50..+200°C, teflon: -100..+250°C, from glass fiber: -100..+400°C.
Attention: Sensor casing – cable connection spot is not waterproof and cannot be submerged with fluids. There is a possibility of making such sensor in a waterproof version. |
![]() ![]() |
TEMPERATURE
SENSOR TA-PK |
|||
Type | Scope of temperatures | Overall dimensions | Usage, comments |
TA-PK-4 |
-50..+250°C -100..+250°C -50..+400°C |
diameter 4 mm, L=100...1000 mm |
For gases and liquids in containers. Sensor
casing is made out of stainless steel. A connector pipe type K2 made
out of stainless steel or type K5 - from brass, nickel is used for
attaching. Cable output form sensors – straight or angular. Scope of cable work temperatures: standard (PCV): -20..+80°C, silicone: -50..+200°C, teflon: -100..+250°C, from glass fiber: -100..+400°C. Attention: Sensor casing – cable connection spot is not waterproof and cannot be submerged with fluids. There is a possibility of making such sensor in a waterproof version. |
TA-PK-6 |
diameter 6 mm, L=100...1000 mm |
||
TA-PK-8 |
diameter 8 mm, L=100...1000mm |
||
![]() ![]() |
TEMPERATURE
SENSOR TA-PM |
|||
Type | Scope of temperatures | Overall dimensions | Usage, comments |
TA-PM-3 |
-50..+180°C -50..+250°C |
diameter 3 m, L=50...500 mm |
For soft mass (i.e. meat) in meat processing
chambers. Handle scope of work temperatures; from silicone: maximum 180°C, from teflon and stainless steel: maximum +250°C. Scope of cable work temperatures: silicone: -50..+200°C, teflon: -100..+250°C. Sensor is waterproof. |
TA-PM-4 | diameter 4 mm, L=50...500 mm |
||
TA-PM-5 | diameter 5 mm, L=50...500mm |
||
![]() ![]() ![]() |
TEMPERATURE SENSORS TA-PD | |||
Type | Scope of temperatures | Overall dimensions | Usage, comments |
TA-PD-4 | -50..+250°C -100..+250°C -50..+400°C |
diameter 4 mm, hole 3,2 mm |
Block surface temperature measurement, device
parts or various construction elements. Scope of cable work temperatures: standard (PCV): -20..+80°C, silicone: -50..+200°C, teflon: -100..+250°C, from glass fiber: -100..+400°C.
Attention: Sensor casing – cable connection spot is not waterproof and cannot be submerged with fluids. There is a possibility of making such sensor in a waterproof version. |
TA-PD-5 | diameter 5 mm, hole 3,2 mm |
||
TA-PD-6 | diameter 6 mm, hole 4,2 mm |
||
![]() |
TEMPERATURE SENSORS TP-111, TP-112 and TP-113 | |||
Type | Scope of temperatures | Overall dimensions | Usage, comments |
TP-111 | -100..+550°C | diameter 4 mm, L=100...800 mm |
For liquids, semi-fluid masses, air. For air temperature measurement (made especially with a terminal TP-113 like in TP-381, without a hole at the end). Cable and handle work temperature -20..+80°C
Attention: Sensor casing – cable connection spot is not waterproof and cannot be submerged with fluids. |
TP-112 | diameter 5 mm, L=100...800 mm |
||
TP-113 | diameter 6 mm, L=100...800mm |
||
![]() |
TEMPERATURE SENSORS TP-131 and TP-132 | |||
Type | Scope of temperatures | Overall dimensions | Usage, comments |
TP-131 TP-132 |
-100..+550°C | L=100...400 mm | For soft mass (i.e. meat). Cable and handle work temperature -20..+80°C. |
![]() ![]() |
TEMPERATURE SENSORS TP-151 and TP-152 | |||
Type | Scope of temperatures | Overall dimensions | Usage, comments |
TP-151 TP-152 |
0..+180°C | L=50...200 mm | For soft mass (i.e. meat) in meat processing chambers. Cable and handle work temperature 0..+180°C |
![]() ![]() |
TEMPERATURE SENSOR TP-155 | |||
Type | Scope of temperatures | Overall dimensions | Usage, comments |
TP-155 | 0..+150°C | L=1000...2500 mm | For loose materials measurement in dumps or in storage yards:
coal, sawdust, peat and biomass (i.e. compost). Cable and handle work temperature0..+150°C |
![]() |
TEMPERATURE SENSORS TP-207, TP-208 and TP-209 | |||
Type | Scope of temperatures | Overall dimensions | Usage, comments |
TP-207 | -200..+550°C | diameter 3 mm L=100...1000 mm |
For liquids, air, surface etc. Sensor is made out of flexible coat cable - an external casing is made out of acid-proof steel. Conductors of a cable are made out of copper with an addition of zircon. Such addition assures resistance supply stability in a wide scope of temperatures. Cable isolation is provided by magnesium oxide. Sensor made in such technology connects in itself advantages of high accuracy and measurement sensor resolution resistance as well as advantages of coat cable in mineral isolation that because of its flexibility and resistance to vibrations allows on measurement in hard industrial conditions. Cable work temperature (from a liquid fiber in a steel screen) and a mediate sleeve -20..+300°C. Upon a special request other cable isolations are possible: PCV, silicone, teflon, casing). Scope of cable work temperatures: PCV: -20..+80°C, silicone: -50..+180°C, teflon: -80..+200°C). Attention: Sensor casing – cable connection spot is not waterproof and cannot be submerged with fluids. |
TP-208 | diameter 5 mm L=100...1000 mm |
||
TP-209 | diameter 6 mm L=100...1000 mm |
||
![]() |
TEMPERATURE SENSORS TP-361 and TP-362 | |||
Type | Scope of temperatures | Overall dimensions | Usage, comments |
TP-361 TP-362 |
-100..+400°C | diameter 2,5, 3, 4, 6, 8 mm L=50...800 mm |
For gases and liquids in containers. A slidable pipe is used for fastening (additional equipment). Scope of cable work temperatures: standard (PCV): -20..+80°C, silicone: -50..+180°C, teflon: -80..+200°C. Attention: Sensor casing – cable connection spot is not waterproof and cannot be submerged with fluids. |
![]() ![]() |
TEMPERATURE SENSOR TP-363 | |||
Type | Scope of temperatures | Overall dimensions | Usage, comments |
TP-363 | -100..+400°C | diameter 4, 6, 8 mm L=50...1000 mm H=50...1000 mm |
For gases and liquids in containers. A slidable pipe is used for fastening (additional equipment). Scope of cable work temperatures: standard (PCV): -20..+80°C, silicone: -50..+180°C, teflon: -80..+200°C. Attention: Sensor casing – cable connection spot is not waterproof and cannot be submerged with fluids. There is a possibility of making such sensor in a waterproof version. |
![]() |
TEMPERATURE SENSORS TP-381 and TP-382 | |||
Type | Scope of temperatures | Overall dimensions | Usage, comments |
TP-381 | -100..+400°C | casing diameter 6 mm, hole diameter 4,2 mm |
Block surface temperature measurement, machine
parts or various construction elements. Scope of cable work temperatures: standard (PCV): -20..+80°C, silicone: -50..+180°C, teflon: -80..+200°C. Attention: Sensor casing – cable connection spot is not waterproof and cannot be submerged with fluids. |
TP-382 | casing diameter 4 mm, hole diameter 3,2 mm |
||
![]() |
TEMPERATURE SENSOR TP-383 | |||
Type | Scope of temperatures | Overall dimensions | Usage, comments |
TP-383 | -50..+150°C | 1,5 x 3,5 x 30 mm | Electric engine winding and other device temperature
measurement. |
![]() |
TEMPERATURE SENSORS TP- 401, TP-402, TP-403 and TP-404 | |||
Type | Scope of temperatures | Overall dimensions | Usage, comments |
TP-401 | -200..+550°C | diameter 6 mm, L=100...800mm | For liquids in containers. Head work temperature -40..+100°C. A slidable pipe and a handle clip are used for fastening. Attention: Sensor casing – cable connection spot is not waterproof and cannot be submerged with fluids. |
TP-402 | diameter 8 mm, L=100...800mm | ||
TP-403 | diameter 10 mm, L=100...800mm | ||
TP-404 | diameter 12 mm, L=100...800mm | ||
![]() |
![]() |
Produced by: LAB-EL Laboratory Electronics 68b, Bodycha Str., 02-495 Warsaw tel: (022) 667 71 18, 0601 209656, fax: (022) 867 53 32 e mail: info@label.com.pl home page: http://www.label.com.pl internet meteorological station: http://www.meteo.waw.pl meteorological station on a mobile phone: wap.meteo.waw.pl Last updated: 03.11.2004 |
![]() |